ANALISIS FAKTOR PENGULANGAN RADIOGRAF (REPEAT ) DI INSTALASI RADIOLOGI RUMAH SAKIT UMUM DAERAH PADANG PARIAMAN
Abstract
On increasing efficiency in producing good radiograph results without wasting material, and time for diagnostic imaging. One of the methods that will be described is repeat analysis which aims to determine the percentage of repetition of radiographs that occur and the causes of repetition of radiographs in the Radiology Installation at RSUD. Padang Pariaman which has an impact on the radiation dose received by patients. Descriptive quantitative research design, conducted directly by observation on Computed Radiography and conventional examination patient register books. The results showed that the repetition rate of radiographs in October to December 2022 at the Radiology Installation of the Padang Pariaman Regional General Hospital was 3.1%. The factor that occurs the most repetition is the equipment factor with a repetition of 22 times with a percentage of 45.83% this repetition occurs because the image that has been exposed when scanned becomes white or there is no image of the object. The percentage of radiograph repetition rates that occur in the Radiology Installation of Padang Pariaman Hospital exceeds the standard tolerance limit set by the Indonesian Minister of Health Number 129 / Menkes / SK / II / 2008 which is ≤ 2%.
Key words: Radiology, Repeat, Computed Radiography
Full Text:
PDFReferences
Atkinson, S., Neep, M., & Starkey, D. (2020). Reject rate analysis in digital radiography: an Australian emergency imaging department case study. Journal of Medical Radiation Sciences, 67(1), 72–79. https://doi.org/10.1002/jmrs.343
Ballinger, P. W. (2012). Merill’s Atlas of Radiographic Position and Radiographic Procedures. Mosby Co.
Direktorat Jenderal Penataan Ruang Departemen Pekerjaan Umum. (2008). Standar Pelayanan Minima Rumah Sakit. Peraturan Menteri Pekerjaan Umum Tentang Pedoman Penyediaan Dan Pemanfaatan Ruang Terbuka Hijau Di Kawasan Perkotaan., 3.
Dwi Lestari. Fatimah. (2019). Jurnal radiografer indonesia, issn 2620-9950. Indonesia, Jurnal Radiografer, 106–110.
Papp, J. (2011). Quality Management in The Imaging Science, (Third Edit). Saint Louis.
Permenkes. (2008). Tentang Standar Pelayanan Minimal Rumah Sakit.ia. Kementerian Kesehatan Republik Indonesia.
Rakhmawati, D., Puspaningrum, A., & Hadiwidjojo, D. (2019). Analisis Pengulang Citra Dengan Menggunakan Digital Radiography Di Instalasi Radiologi Rumah Sakit Panti Waluyo Surakarta. J. Pijar MIP14, 14(1), 1–12.
Shetty, M. C. (2010). Computed Radiography Image Artifacts Revisited. Kranataka.
DOI: http://dx.doi.org/10.30633/jkms.v15i2.2801
Refbacks
- There are currently no refbacks.
e-ISSN : 2540-9611
p-ISSN : 2087-8508
Publish by Stikes Syedza Saintika Padang (Jl. Prof. Dr. Hamka No. 228 Air Tawar Timur Padang)
Contact Person :
Ns. Honesty Diana Morika,M.Kep
Editor In Chief
Pusat Penelitian dan Pengabdian Masyarakat
STIKes SYEDZA Saintika Padang
Phone: 082384992512
Wiya Elsa Fitri, M.Si
Editor
Pusat Penelitian dan Pengabdian Masyarakat
STIKes SYEDZA Saintika Padang
Phone: 08116609525
Jl. Prof. Dr. Hamka No. 228 Air Tawar Timur Padang - Sumatera Barat
Email: lppmsyedza@gmail.com
This work is licensed under a Creative Commons Attribution 4.0 International License.
View My Stats